Showing results: 2116 - 2130 of 2454 items found.
-
Extech MA620 -
Extech Instruments Corporation
MA620 is a True RMS, autoranging AC clamp meters offer plant maintenance techs, electrical troubleshooters, and DIYers a test instrument that delivers a combination of high performance and exceptional value. In addition to a host of advanced multimeter and current measurement capabilities, it also has a built-in, non-contact (NCV) voltage detector. You can select auto- or manual-ranging modes, measurement functions cover all types of troubleshooting over and above noninvasive current probe measurements: voltage, resistance, capacitance, frequency, duty cycle, diode and continuity tests. Even measure temperature with the supplied Type K bead wire probe. Complete with test leads, general purpose Type K bead wire temperature probe, 9V battery and carrying case.
-
TOB-IT8512 -
Xiamen Tob New Energy Technology Co., Ltd
IT8512 120V/30A/300W DC Programmable Electronic Load for Battery and Power Supply TestHigh performance and affordable single channel DC electronic load. TOB-IT8512 DC electronic loads provide you with the flexibility to test a wide range of applications from power supply, charger to battery. The high resolution voltage(1mV), current(0.1mA) measurement system provides both accuracy and convenience, and eliminates the need for a DMM, external shunts and wiring.
-
64970 -
Lisle Corp.
Replaceable in-line fuses protect both the meter and tester in the event a high current source on the vehicle is left on. The multimeter is bypassed with the switch during connection in case of a power surge. The tester and meter can remain connected until other computer systems shut down, isolating the drain. As a convenience, stacking banana connectors are used on the tester. This allows voltage to be measured on various locations on the vehicle during the drain test, using standard test leads.
-
62000H-S -
Chroma Systems Solutions, Inc.
Solar Array Simulator DC Power Supplies by Chroma provide programmable simulation of Voc (open circuit voltage) up to 1800V and Isc (short circuit current) up to 30A. The 62000S-H series provides an industry leading power density in a small 3U high package. The Solar Array Simulator is highly stable and has a fast transient response design, which are both advantages to MPPT performance evaluation on PV inverter devices.
-
95X -
Xitron Technologies Inc.
Vitrek built the 95X Series from the ground up with DSP technology – to bring you the safest, fastest, most capable, feature rich hipot testers available. The 95X Series combines high output power, with a wide range of AC & DC voltage outputs and extremely low leakage current measurement. Then we added a 4-wire milli-ohmmeter with dynamic range up to 100K ohms and an overlapping Tera-ohm class Insulation Resistance function.
-
N8700 Series -
Keysight Technologies
The Keysight N8700 Series ATE system power supply delivers high current with low noise in a compact two unit package. Airflow moves front to back, so no additional space is required above or below the power supply in your automated test equipment (ATE) rack. This series of programmable power supplies sources up to 3300 or 5200 W. Get output voltages from 8 to 600 V and 5.5 to 400 A.
-
IBEKO Power AB
DV Power has released a new generation of circuit breaker test equipment for condition assessment of medium and high voltage circuit breakers.Field-portable instruments with standalone or PC controlled functionality, allow performing various tests during circuit breaker manufacturing, commissioning and maintenance stages.Applications supported by the DV Power test equipment include measurements of:Contact resistanceDRM (dynamic resistance measurement)Coil resistance and coil current (IEC 62271-100)Mechanism charging time (IEC 62271-100)Minimum trip voltage (IEC 56, ANSI C37.09)Undervoltage release (IEC 60694)The timing of a circuit breaker’s main, auxiliary and pre-insertion contactsSynchronization between the contactsMotion and velocity“First trip” testThe essential part of a circuit breaker condition assessment is the ability to compare the latest test results with the previous testing. Accordingly, our instruments store measured values and compare them to a manufacturer’s limits. Also, a fingerprint obtained in this way can be used at a later stage as a reference during subsequent measurements. In order to obtain an accurate comparison, the tests need to be performed using identical test parameters. Consequently, any deviation and change in the test results may indicate the circuit breaker condition deterioration. Even more, to overcome this issue, DV-Win enables test plans and graph overlay features.Finally, as a final result of a circuit breaker maintenance process, the DV-Win provides analytical tools and customized report creations.
-
STW-9800 Series -
Texio Technology Corp.
* 200VA AC Test Capacity* 240 x 64 Ice Blue Dot Matrix LCD* Manual/Auto Mode* Function Key for Quick Selecting* High Intensity Flash for Caution & Status Indication* Safety Interlock Function* True RMS Current Measurement * High Resolution : 1μA for Measuring Current, 2V for Setting Voltage* PWM Switching Amplifier to Enhance the Power Efficiency and Reliable Testing* Max. 100 Memory Block for Test Condition (Step) Setting. And Each Step can be Named Individually* Remote Terminal on the Front Panel for“Start”and“Stop” Control by External* Interface: RS-232C, USB Devise, Signal I/O and GP-IB (Option: OPT.1)
-
RP4030 -
Teledyne LeCroy
The Teledyne LeCroy RP4030 Power Rail Probe meets the specific requirements of those who need to acquire a low-voltage DC signal as part of a:-Comprehensive power integrity, digital power management IC (PMIC), voltage regulator module (VMR), point-of-load (POL) switching regulator, or low-dropout regulator testing- Complete embedded power management system that includes PMICs, VRMs, POLs, and LDOsThe RP4030 will faithfully acquire a low-impedance, low-voltage DC power/voltage rail signal without unduly loading the device under test (DUT), while providing high offset to allow DC power/voltage rail signal display on an oscilloscope with high gain.
-
17040 -
Chroma ATE Inc.
Conforms to international standards for battery testing: IEC, ISO, UL, and GB/T, etc.Regenerative battery energy discharge (Eff. >90%, PF >0.95, I_THD <5%)Multiple voltage and current ranges for auto ranging function to provide optimum resolutionHigh accuracy current/voltage measurement (0.05%FS/0.02%FS)2ms current slew rate (-90% ~ 90%)Dynamic (current/power) driving profile simulation tests for NEDC, FUDS, HPPCTest channel parallel functionTest data analysis functionData recovery protection (after power failure)Automatic protection for error conditionBattery simulator (option)High power testing equipment- Voltage range : 80~1000V - Current range : 0~750A - Power range : 0~300kWCustomized integration functions- Integrated temperature chamber - BMS data analysis - Multi-channel voltage/temperature recording
-
PHG 80 TD/PD -
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR PHG 80 TD/PD. With the PHG TD/PD, you get a multifunctional cable testing and diagnostics system that was specially designed and developed for medium-voltage networks. The PHG TD/PD system is also the only cable testing and diagnostics system that gives a comprehensive overview of the quality and ageing condition of the test sample. The diagnostic methods TD and PD are mutually complementary, because on one hand you can detect the complete condition and on the other hand locate individual faults in the operating resources.* High performance VLF truesinus testing device (3 kW) with regulated output voltage* Compact, enclosed design in 19" format* Variable installation option with separate control and voltage unit* Variable connection options to cable stations of different models
-
779620-01 -
NI
16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sinking DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6233 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, sinking digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6233 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6233 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
779616-01 -
NI
8 AI (16-Bit, 250 kS/s), 4 AO, 6 DI, 4 DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6230 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 5 V TTL/CMOS signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6230 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6230 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
779618-01 -
NI
16 AI (16-Bit, 250 kS/s), 2 AO, 6 DI, 4 Sourcing DO, Bank-Isolated, PXI Multifunction I/O Module—The PXI‑6232 is a bank-isolated DAQ device designed for voltage I/O. It offers analog I/O, digital input, sourcing digital output, two 32‑bit counters, and digital triggering. The digital input and outputs are compatible with 24 V signals. It combines the safety and performance benefits of isolation with high-performance timing, amplification, and calibration technologies to offer accurate measurements and precise control. The PXI‑6232 is ideal for test, measurement, control, and design applications in environments with high voltages and electrical noise. You can use the PXI‑6232 to read from encoders, flow meters, and proximity sensors as well as control valves, pumps, and relays.
-
Pasternack Enterprises, Inc.
Pasternack's low phase noise amplifiers cover select frequency bands ranging from 1.5 to 18 GHz with residual phase noise levels as low as -180 dBc/Hz @ 10 KHz offset. Additional performance specs include small signal gain ranging from 9 to 14 dB, with typical noise figure of 5.5 dB. Psat levels for these amplifiers range from +16 to +25 dBm with Output IP3 levels as high as +34 dBm. All models feature single DC voltage supplies and input/output RF ports are internally matched for 50 ohms with DC blocking capacitors. These compact module assemblies require no external components and are available in rugged Kovar metal drop-in packages that are gold-over-nickel-plated and support field replaceable SMA connectors. All models are EAR99 and guaranteed to meet MIL-STD-883 test conditions for hermeticity and temperature cycle.